Online UPS

EH9315 Three Phase Series (20-40KVA)

ModelEH9315-20KS, EH9315-30KS, EH9315-40KS

Online UPS — High Frequency Three Phase(3/1) Online UPS (20KVA/18KW / 30KVA/27KW / 40KVA/32KW)

At a glance

Rated Capacity
20KVA/18KW / 30KVA/27KW / 40KVA/32KW
Output Voltage
220/230/240VAC

Series ranges may cover several models. Confirm your required configuration with our team.

View comparison shortlist

0 / 3 selected in this product family. Your shortlist stays in this tab.

Ask our team for current pricing and availability for this model.

Applications

Backup Power / Critical Power (UPS)

Key features

  • Double-conversion online design with zero output transfer time.
  • DSP digital control for a stable, reliable system.
  • Active power factor correction (PFC) close to 1, reducing grid pollution.
  • Ultra-wide input voltage range — accepts voltages as low as 208V without switching to battery power.
  • Automatically adapts to 50/60Hz, compatible with fuel generators.
  • LCD + LED real-time display of UPS operating status.
  • Self-diagnosis at startup detects hidden faults.
  • Comprehensive protection: over/under-voltage, overload, short-circuit, temperature and battery overcharge.
  • Efficiency up to 94.5%, reducing power loss.
  • Standard RS232 interface with optional SNMP card for remote monitoring.
  • Cold-start capability directly from battery.
  • Input phase-sequence protection prevents incorrect phase wiring from powering on.

Specifications 30 details

ModelsEH9315-20KS, EH9315-30KS, EH9315-40KS
Rated Capacity20KVA/18KW / 30KVA/27KW / 40KVA/32KW
AC Input Connection Type3W+N+PE
Rated Input VoltageAC 380V/400V/415V
Voltage RangeAC 208V~478V
Frequency Range45-55Hz at50Hz/54-66Hz at60Hz (Auto Sensing)
Input Power Factor≥0.99
Input current Harmonics≤3% (100% Non-linear Load)
Bypass RangeBypass protection voltage upper limit: 220V: +25% (optional: +10%, +15%,+25%)230V: +20% (optional +10%, +15%)240V: +15% (optional +10%)
AC Output Connection TypeL+N+PE
Output Voltage220/230/240VAC
Output Power Factor0.8/0.9
Output Accuracy±1%
Output FrequencyOnline mode: follow the mains frequency, battery mode: 50/60Hz±0.2%
Output Harmonic Distortion≤ 2% linear load; ≤ 5% non-linear load
Number Of BatteriesOptional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs)Default: DC±192V
Recharging Current10A max
Switching TimeMains mode to bypass mode: 0ms; Mains mode to battery mode: 0ms
Normal mode (full load)≥Efficiency 94.5%
Communication InterfaceRS232, RS485, SNMP card (optional), relay card (optional)
Overload ProtectionLoad ≤ 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150%, immediately transfer to bypass
Over Temperature ProtectionNormal mode: switch to bypass mode; battery mode: turn off the output immediately
Emergency Shutdown (EPO)Turn off output immediately
Maintenance BypassStandard maintenance bypass switch
Operating Temperature0~40℃
Storage Temperature-25~55℃ (Battery: 0~40℃ )
Relative Humidity0%~95% (no condensation)
AltitudeAltitude <1500m, when it exceeds 1500m, use derating according to GB/T 3859.2
Overall Volume (D*W*H) (mm)690*250*734
Net Weight (kg)46 / 47 / 48