Online UPS

EH9335 Rack Mount Series (10-40KVA)

ModelEH9335- 10KRS, EH9335- 15KRS, EH9335- 20KRS, EH9335- 30KRS, EH9335- 40KRS

Online UPS — High Frequency Three Phase(3/3) Rack Mount Online UPS

At a glance

RatedPower
10KAVA/9KW / 15KVA/13.5KW / 20KVA/18KW / 30KVA/27KW / 40KVA/32KW
Output Voltage
AC 380V/400V/415V

Series ranges may cover several models. Confirm your required configuration with our team.

View comparison shortlist

0 / 3 selected in this product family. Your shortlist stays in this tab.

Ask our team for current pricing and availability for this model.

Applications

Backup Power / Critical Power (UPS)

Key features

  • Double-conversion online design with 0ms transfer, single input and output voltage.
  • DSP digital control for a stable, reliable system.
  • Active power factor correction (PFC) close to 1, reducing grid pollution.
  • Ultra-wide input voltage range.
  • Input frequency range of 40-70Hz, compatible with fuel generators.
  • LCD + LED real-time display of UPS operating status.
  • Self-diagnosis function detects hidden faults.
  • Comprehensive protection: over/under-voltage, overload, short-circuit, temperature and battery overcharge.
  • Efficiency up to 94.5%, reducing power loss.
  • Cold-start capability directly from battery.
  • Automatic recovery, reconnection and battery charging when utility power returns.
  • Standard RS232 communication interface for multifunction monitoring.

Specifications 33 details

ModelsEH9335- 10KRS, EH9335- 15KRS, EH9335- 20KRS, EH9335- 30KRS, EH9335- 40KRS
RatedPower10KAVA/9KW / 15KVA/13.5KW / 20KVA/18KW / 30KVA/27KW / 40KVA/32KW
Input formatThree-phase four- line+ground
Rated input voltageAC 380V/400V/415V
Voltage rangeAC 208V~478V
Frequency range45-55Hz at50Hz/54-66Hz at60Hz (Auto sensing)
Input power factor≥0.99
Input current harmonic≤3% (100% Nonlinear load)
Bypass rangeBypass protection voltage upper limit: 220V: +25% (Optional +10%, +15%, +25%)230V: +20% (Optional+ 10%, +15%)240V: +15% (Optional+10%)
OutputThree-phase four-line + ground
Output VoltageAC 380V/400V/415V
Output power factor0.8/0.9
Output range±1%
Output frequencyOnline Mode: following utility electricity frequency, battery mode: 50/60Hz±0.2%
Load peak ratio3:1
Output harmonic distortion≤ 2% Linear Load ≤ 5% Nonlinear Load
Battery NumberOptional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs) Default: DC±192V
Charging Current10A max
Overload ProtectionLoading ≤ 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150% change to bypass
Over temperatureNormal mode: change to bypass mode; Battery mode: stop output
Emergency shutdown (EPO)Stop output
Change-over timeUtility mode to bypass mode: 0ms (tracking); utility mode to battery mode: 0ms
Normal mode (Full load)≥efficiency 94.5%
Communication ConnectionRS232,RS485,SNMP (Optional)
ECO modesupport
Self-test functionsupport
Parallel functionMax 4pcs
Working temperature0~40℃
Storage Temperature-25~55℃ (batteries: 0~40℃ )
Relative humidity0%~95% (no condensation)
Altitude< 1500m, when above 1500m, when above 1500m, derate according to GB/T 3859.2
Size (D*W*H) (mm)580*443*131
Net Weight (kg)32 / 32.5 / 33 / 33.5 / 34